Fluke Ti25 Thermal Imager Camera View larger

Fluke Ti25 Infrared Camera

Fluke Ti25

New product

Sell New Fluke Ti25 Infrared Camera

More details

$2,250.00

$2,250.00 per Unit

More info

Fluke Ti25 Infrared Camera

  • Enhanced problem detection and analysis capabilities with IR-Fusion® Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal, picture-in-picture, or automatic blend visual and thermal images.
  • Optimized for field use in harsh work environments.
  • Engineered and tested to withstand a 2 m (6.5 ft) drop - ;When was the last time you dropped a tool?
  • Withstands dust and water—tested to an IP54 rating.
  • Delivers the clear, crisp images needed to find problems fast.
  • Identify even small temperature differences that could indicate problems with excellent thermal sensitivity (NETD).
  • Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
  • Reflected background temperature (reflected temperature compensation)
  • No need to carry pen and paper—record findings by speaking into the camera. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference.
  • Everything needed to get started is included.
    Training DVD is now included free. See how easy it is to set up your thermal imager, create professional reports with SmartView software and learn thermography theory with step-by-step video instructions.
  • Adjustable hand strap for left-or right-handed use.
Temperature
Temperature measurement range (not calibrated below -10°C) -20°C to +350°C (-4°F to + 662°F) (two ranges)
Temperature measurement accuracy ± 2°C or 2% (whichever is greater)
On-screen emissivity correction Yes
Imaging Performance
Field of view 23° x 17°
Spatial resolution (IFOV) 2.5 mRad
Minimum focus distance Thermal lens: 15 cm (6 in)
Visible (visual) light lens: 46 cm (18 in)
Focus Manual
Image frequency 9 Hz refresh rate
Detector type 160 X 120 focal plane array, uncooled microbolometer
Infrared lens type 20 mm F = 0.8 lens
Thermal sensitivity (NETD) ≤ 0.09°C at 30°C target temp. (90 mK)
Infrared spectral band 7.5 μm to 14 μm
Visual camera 640 x 480 resolution
Image Presentation
Palettes Ironbow, blue-red, high contrast, amber, hot metal, grey
Level and span Smooth auto-scaling and manual scaling of level and span
Minimum span (in manual mode) 2.5°C (4.5°F)
Minimum span (in auto mode)
Fast auto/Manual range toggle Fast auto rescale
5°C (9°F)
IR-Fusion® information Full infrared with MAX, MID, or MIN automatic blending; and picture-in-picture with MAX, MID, or MIN automatic blending (Visual and IR blending)
Picture-In-Picture (PIP) Three levels of on-screen IR blending displayed in center 320 x 240 pixels
Full screen (PIP off) Three levels of on-screen IR blending displayed in center 640 x 480 LCD
Image Capture and Data Storage
Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager
Storage medium SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations or 3000 basic (.bmp) IR images)
File formats Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp) files
Export file formats w/ SmartView® software JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF
General Specifications
Operating temperature -10°C to +50°C (14°F to 122°F)
Storage temperature -20°C to +50°C (-4°F to 122°F) without batteries
Relative humidity 10% to 90% non-condensing
Display 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto)
Controls and adjustments User selectable temperature scale (°C/°F)
Language selection
Time/Date set
Software SmartView® full analysis and reporting software included
Batteries Internal rechargeable battery pack (included)
Battery life Three to four hours continuous use (assumes 50% brightness of LCD)
Battery charge time Two hours for full charge
AC operation/charging AC adapter/charger (110 V AC to 220 V AC, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal AC mains adapters included.
Power saving Sleep mode activated after 5 minutes of inactivity, automatic power off after 20 minutes of inactivity
Safety standards CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2
Electromagnetic compatibility EN61326-1
C Tick IEC/EN 61326
US FCC CFR 47, Part 15 Class A
Vibration 2 G, IEC 68-2-29
Shock 25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides}
Drop 0.27 x 0.13 x 0.15 m (10.5 x 5 x 6 in)
Dimensions (H x W x L) 1.2 kg (2.65 lb)
Weight (battery included) 2 G, IEC 68-2-29
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard)
Recommended calibration cycle Two-years (assumes normal operation and normal aging)
Supported Languages Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish